Short answer: Have an industrial bandsaw professionally serviced at least once a year on single shift work, and every six months on double shift or heavy production work. Between services, operators should carry out simple daily, weekly and monthly checks. Regular maintenance is also part of your legal duty under PUWER.
Why servicing matters
A bandsaw that is out of adjustment cuts crooked, eats blades and wastes material. Most of these problems build slowly, so they are easy to miss until a customer rejects a batch. A planned service catches worn guides, leaking hydraulics and loose wheels before they cost money.
There is also a legal side. The Provision and Use of Work Equipment Regulations 1998 (PUWER) require work equipment to be maintained in an efficient state and in good repair. HSE guidance on maintenance of work equipment explains what that means in practice.
Recommended service intervals
|
Usage |
Professional service |
|
Light or occasional use |
Every 12 months |
|
Single shift, 5 days a week Every 12 months |
Every 12 months |
|
Double shift or heavy solids |
Every 6 months |
|
24 hour or high volume production |
Every 3 to 6 months |
Operator checks between services
Daily
Clear swarf from the vice, table and chip tray
Check coolant level and flow at the blade
Check the chip brush touches the teeth
Look for damaged teeth before starting
Release blade tension at the end of the day
Weekly
Check blade guides and guide pads for wear
Check coolant concentration with a refractometer
Clean the coolant tank strainer
Check blade tension with a tension meter
Monthly
Check hydraulic oil level and look for leaks
Lubricate slides and pivot points
Check emergency stops and guards work
What a professional service covers
A Saws UK service engineer typically checks and adjusts:
Wheel alignment, wheel bearings and blade tracking
Blade guides, guide arms and squareness of the head to the vice
Hydraulic system, feed control and descent rate
Gearbox oil, drive belts and motor
Vice, shuttle and measuring systems on automatic machines
Electrical safety devices, guards and emergency stops
Coolant system and pump
You receive a written report listing work done and any parts needed. See our parts and servicing page for details.
Do not forget extraction
If your saw is fitted with local exhaust ventilation, COSHH requires the LEV system to be thoroughly examined and tested at least every 14 months. See HSE guidance on local exhaust ventilation. Our Comet EX extraction range is designed for sawing and machining workshops.
FAQs
Do you service brands you did not supply? Yes. We service most major bandsaw and circular saw brands.
How long does a service take? Most single machine services are completed in one visit.
Can you supply parts for older machines? Often, yes. See our spare parts page.
Talk to us
Book a service or set up a planned maintenance contract. Email [email protected].